Title:

The use of 'flight diverters' reduces mute swan Cygnus olor collision with power lines at Abberton Reservoir, Essex, England

Author(s):
Publication Year:
2008
Abstract:

In the spring of 2004, nine mute swans were killed through collision with the 132Kv power lines, while in spring 2006, 21 were killed. In the summer of 2006, over 500 red 'flight diverters' (320 mm long, 175 mm diameter) were installed at 5 m intervals along a 1.5 km length of the power lines. In the spring of 2007 only one mute swan was killed through power line collision, while in spring 2008 none were killed. The perpendicular distances over which bird carcasses were found on the ground from under the overhead power cables ranged from 10-351 m. This should be taken into account when designing future collision mortality surveys for similar power lines. It is recommended that appropriate bird flight diverters are fitted as routine best practise when installing any new overhead power lines.

Publication Title:

Conservation Evidence

Volume:
5
Pages:
83 - 91
Item Type:
Journal Article
Language:
en